Battery
Running Load of 150Ah - C10 Battery
150Ah - C10 150/10=15Amps 15*12v= 180 watts Inverter Consumption 30-40watts 180-40 = 140 watts 140 watts*2 Battery = 280wattsBackupCaution If Battery Exceeds this load or taking higher amps Battery gets over heated and life time gets reduced
150 AH battery at C10 will last for 10 hours on a load of 15 Amps 140*10= 1400 watts Total Power we can StoreDifferent Battery Rating Comparison
A 150 AH battery at C20, will last for 20 hours on a load of 7.5 A. A 150 AH battery at C10 will last for 10 hours on a load of 15 A. A 150 AH battery at C5 will last for 5 hours at a load of 30 A.
Solar Panel
UTL Gamma+ MPPT Inverter
1 Battery 24v Panel can be used Rs.36000 Starting Heliac 165*4 watts panel =660 150Ah 36+24 month warranty 150-200 Units